With the equipment de-energized, remove the plastic cover and trace the braid to the first piece of metal that grips it. Follow that metal to the connector shell, then to the mating shell or panel bond called out in the design. The first unexplained gap on the section is the place to investigate. A shaded region labeled “shield” often covers the whole junction without showing either contact surface.
Draw a section through one termination, including the cable construction and the equipment interface. Indicate whether the screen is an overall braid, individual pair screens, foil with a drain wire, or a combination. These constructions need different preparation and contacts. Also identify the grounding or bonding arrangement specified by the equipment designer at each end of the cable. A hood supplier cannot infer that decision from the color of the jacket.
Product design illustrations.
Identify the component that captures the braid
A band may clamp an exposed braid around a conductive landing, or a ferrule can capture the braid against a mating sleeve. Some connectors use a separate shield insert inside a polymer enclosure. TE illustrates a circumferential termination on its Micro-D and D-sub products. That provides an example of the metal-to-metal interface a section should show. For a custom hood, identify the actual termination system and the allowed range of cable preparations on its own drawing. TE Micro-D and D-sub screen termination overview.
Trace the next contact point. A ring can make excellent contact with the braid yet sit in a plastic pocket isolated from the connector frame. Conversely, a metal bracket can touch the frame without ever reaching the stripped screen. Explode the assembly and mark the two mating faces at each junction. Identify surface finish, contact hardware and the feature that keeps those faces engaged after assembly.

Assign the clamp that handles cable loads as well. The braid termination and jacket restraint may be separate components, even when they are close together. A tensile load that slides the jacket backward can disturb the termination without visibly damaging the outer hood. Trace the strain-relief load path through the D-sub hood before adding molded ribs that squeeze the braid or its ferrule.
Give the plastic a job you can measure
An ordinary unplated insulating cover can locate the ferrule, protect the prepared cable and keep the hardware away from the wires. Dimension its pocket from the faces that position the metal connector. Check the largest permitted band buckle or crimp outline at the orientation in which the harness shop can actually leave it. If the lid bottoms on a buckle before seating, tightening the cover screws can tilt the termination hardware.
Look at the assembly sequence as well as the finished section. A pocket that fits a completed ferrule might obstruct the crimp die or banding tool. There may be no need to enlarge the pocket if the hardware can be terminated first and then loaded from the side. If a closed sleeve has to slide on before stripping the cable, the work instruction and the delivered parts kit need to make that sequence possible.

Conductive coatings or formulated conductive polymers change the problem. They require a defined interface to adjacent metal, a contact design and a verification plan for the actual finish or formulation. A silver-colored decorative finish and the words “shielded cable” on the bill of materials do not specify that interface. Keep a coated design distinct from an uncoated cover surrounding a separate metal shield.
Choose the test for the question being asked
On a disconnected assembly, a continuity check at defined points can find an open connection or a missing contact. Choose the method, connection points and acceptance limit with the electrical designer. A basic meter cannot establish shielding effectiveness over an operating frequency range. A narrow conductor may show DC continuity and still behave differently at high frequencies from a well-bonded circumferential termination.
Include the panel and mating half when they form part of the specified path. A bench clip connected directly to the connector frame can bypass the mounting interface that production relies on. Record whether the test used an unpainted panel, a finished enclosure, a gasket or a mounting strap. Otherwise two teams may report very different results while testing different paths on nominally identical cables.

Preserve an assembly-stage inspection view where practical. Braid foldback, stray strands and the position of the hardware are easier to see before the lid closes. Agree who approves the cable preparation, termination and final electrical checks. The molding drawing can control a pocket and its seating faces precisely while the harness work instruction controls the conductive joint assembled into them.
On the section of the plastic backshell, draw the electrical test leads as well as the conductive hardware. If one clip lands on the ferrule and the other on the connector frame, that reading says nothing about the bond from the frame to the finished panel. A second pair of test points can isolate that interface when the equipment design relies on it.