Precision connector components · Made to your design

Custom Keyed Plastic Housings for FAKRA Connectors

A keyed plastic outer housing guides a FAKRA connector pair together and holds the coax insert in the position specified on the assembly drawing. FECISION quotes the injection mold and empty plastic bodies for your single- or dual-position design.

Send the mating-face view, the section through the insert seat and the part revisions you are authorized to share. If several codes share the same outer envelope, mark which ribs, grooves, colors and port positions change. This lets us compare common tooling with separate cavities for each variant.

Empty keyed plastic coax connector housings arranged on a tooling fixture
Keyed Plastic Housings for FAKRA Connectors · Product design illustrations

Application fit

Fit the housing into the harness or equipment assembly

A correct front profile leaves some practical questions open. At the rear, the assembler needs room to load the insert and confirm engagement. At the front, a release tab beside a bracket can become inaccessible once the harness is installed.

Rear entry and side retention features of an empty plastic coax housing on a fixture
Rear loading and service clearanceInclude the terminated cable and its ferrule in the assembly envelope. Mark the insertion path and the space available to push the insert home or use the specified release tool.

Harness-side single housings

Provide the cable-side insert and termination envelope. A molding with sufficient clearance for the bare insert can still obstruct the ferrule during loading. Show the orientation in which a technician can access the latch after clipping the harness in place.

Dual-port equipment interfaces

Share the equipment-side mounting datums, assembled port positions and permitted float. If the two coax inserts load separately, identify which rear port corresponds to each keyed position on the mating face.

Families of coded housings

Create a part-number list that ties the mechanical profile to its color requirement, permitted counterpart and order quantity. Where a drawing calls for an incompatible mate to be excluded, identify the specific counterpart and the required check.

Quote-ready inputs

What to send for a meaningful quotation

Use the same drawing revision and quantities when comparing proposals. If you need supplier approval before releasing CAD, start with your production-site qualification requirements and a non-confidential description of the work.

Project-specific inputs and review boundaries
AreaPlease provideReview before release
Mating interfaceAuthorized interface revision, mating-face view, key and latch orientation, counterpart part number.Resolve view direction and define which references establish key position and permitted engagement.
Coax insert and lockInsert outline and revision, stop and retention geometry, loading direction, ferrule envelope and any secondary lock.Review axial seating, latch access and tool release for the local retention features.
Mounting and port positionSingle or dual layout, port axes, mounting references and bracket or panel envelope.Compare the assembled cable exit and release path with the available space.
Material, color and quantitiesRequired resin grade, approved color reference, sample quantity and repeat quantities for each part number.Evaluate keyed cavity variants and color changeovers against the expected order mix.
AcceptanceCritical plastic dimensions, approved counterpart list and project-specific insertion and retention test methods.Agree which checks use loose moldings and which require customer-specified components and fixtures.

From drawing to approval

From the interface drawing to a sample that can be checked

Keyed coax connector shell in an aluminum fixture beneath a vision inspection head
Inspect the loose key before the fit checkUse the agreed drawing datums to examine the molded key. Record the mating connector and insert revisions separately for the assembled fit test so a failed check can be traced to the right interface.
  1. Pair the drawings

    Place the housing and counterpart in their installed orientation. Select a common mating reference, mark the latch side and trace where the keyed ribs enter. Record the part numbers and revisions used for the review.

  2. Lay out the mold details

    Review steel access to the key, insert stop and retention windows. For a family of codes, assess whether a local cavity change can form each profile without disturbing common seats or moving a parting line onto a critical edge.

  3. Inspect the first moldings

    Measure the nominated plastic dimensions by cavity. Examine thin key edges and lock windows for flash, then confirm the color reference for that specific part number under the agreed viewing conditions.

  4. Check fit with the specified hardware

    Load the intended coax insert and check seating and retention. Mate and release the approved counterpart in its mounting position. Where the program requires RF qualification, use the agreed complete connector and cable configuration for that test.

Before you request a quote

Can you quote a replacement housing from a color and a photograph?

A photograph can start the discussion. To price production tooling, send the authorized interface definition, mating part and insert references, and show what must change from the pictured part. The color alone does not define key geometry or establish interchangeability.

What changes when two coax positions share one housing?

Both port axes and their orientation must line up with the mating assembly. Send the port spacing, mounting references and permitted movement of the counterpart. A rigid pair on an equipment module gives a different fit condition from two independently handled cable ends.

Can several codes share the tooling?

Send each mechanical profile, its approved color and expected quantities. A local rib change may be possible with a replaceable tool detail. Changes to the axial seat, latch, port spacing or tool release can alter that decision.

Does the plastic housing quote include RF performance qualification?

The base quote covers the drawing-defined molding. If your program needs an RF result, specify the coax insert, cable, termination, mating assembly, test method and party responsible. Inspection of the empty housing establishes only the plastic features tested.

Your next step

Discuss the part with its intended function.

Send the permitted housing and mating-interface revisions, the coax insert section and order quantities by code. If a drawing cannot be released yet, a non-confidential envelope and a list of the interfaces you need to preserve are enough to start the discussion.

Explore our connector injection molding service or review other connector components and mold inserts.

Request A Quote

Tell Us About Your Project

Fields marked with are required.

Before uploading sensitive files, agree any NDA and permitted sharing with your FECISION contact and the selected manufacturing partner. If you need an NDA first, select “NDA before drawings” above and send only a non-confidential overview.

By submitting this form, you agree that Fecision may use the supplied information to respond to your inquiry.