info@fecision.com

Precision connector components · Made to your design

Custom Hybrid Power and Signal Connector Housings

Bring power and signal contacts into one keyed connector body. FECISION quotes the custom molded housing around the two terminal families, from the mating-face layout to the stops and retention features inside each cavity.

For a tooling review, send one drawing for each terminal, a numbered mating-face view and the mating connector outline. Mark which positions are populated in each variant. These details determine which cavities can share tooling and what the first molded samples need to demonstrate.

Rectangular molded connector housing with two sizes of contact opening and separate crimp terminals on a workbench
Hybrid Power & Signal Housings · Product design illustrations

Application fit

Choose the housing layout around the harness build

A mixed-contact body can bring two branches to the equipment in one mating operation. The saving is most useful when the wires can also be loaded, retained and serviced with the housing in its installed position.

Rear of a connector with large and small wires loaded and an extraction tool alongside the housing
Check the second contact to be installedLay the intended insertion and service tools against the wire-entry face with neighboring positions populated. A cavity that is accessible on an empty sample may be blocked by the first cable installed.

Equipment power and control harnesses

A shared plug can carry a supply branch and low-level control wiring to the same module. Show where each wire leaves the housing and which circuit must remain accessible after the harness is tied down.

Serviceable cable-to-device interfaces

Where a contact may need replacement, show the release tool and the connector position during service. A removable shroud or a different loading order can be evaluated before changing the entire cavity pitch.

Multiple circuit populations

Define each sellable configuration on its own cavity map. A terminal left out, a separate blanking plug and a position molded closed make different demands on tooling, parts supply and assembly control.

Quote-ready inputs

What to send for a meaningful quotation

Use the same drawing revision and quantities when comparing proposals. If you need supplier approval before releasing CAD, start with your production-site qualification requirements and a non-confidential description of the work.

Project-specific inputs and review boundaries
AreaPlease provideReview before release
Cavity map and mating partKeyed mating-face view, cavity identifiers, counterpart revision and installed orientation.Confirm which circuit sits in each location and how the molded shell locates the mating pair.
Power and signal terminalsBoth terminal drawings, finished crimp sections, insertion direction and service-tool envelopes.Review each stop, locking feature and release path with the adjacent positions populated.
Material and separationSpecified resin grade and conditioning, required insulating features, service environment and any applicable customer drawing limits.Identify the walls and spaces to inspect on the housing. Agree how the loaded connector will be tested against its electrical requirements.
Variants and quantitiesPopulation map, blank or plug decisions, unique keying and trial and repeat quantities for each version.Identify common steel, version-specific inserts and the means of keeping variants separate during production.
Acceptance evidencePart datums, critical cavity dimensions, sample counterpart and terminal availability, and the reports required.Distinguish measurements taken on the bare part from retention, mating or electrical tests on an assembled sample.

From drawing to approval

From two terminal drawings to a first-sample review

Mixed-cavity connector housing located against stops on an optical inspection stage
Inspect both patterns from the same referencesLocate the empty housing from the agreed mounting and key surfaces. Record the large and small cavity positions separately so a shift affecting one group remains visible.
  1. Trace the two insertion paths

    Follow the largest feature of each terminated contact from the rear opening to the seated position. Mark its stop and the space needed for the locking feature to recover. Review what happens if an operator offers the smaller terminal to a power cavity.

  2. Review neighboring features in the mold

    Identify how each stepped core is supported and where the wall thickness changes between power and signal cavities. For variants, compare replaceable core blocks against the size of the change, the working steel around it and the expected volume split.

  3. Measure the loose housing first

    Inspect a numbered map of the empty cavities against the drawing references. Record the mold cavity and resin condition with the results. If the full pattern appears displaced, check how the housing was seated before adjusting an individual core.

  4. Trial the intended population

    Verify terminal loading and removal with representative crimps, neighboring wires and any secondary lock. Agree a separate route for mating-force, current-carrying or signal-performance checks using the actual counterpart and required test setup.

Before you request a quote

Can I request a quote with only the wire gauges?

Wire sizes help describe the harness. A preliminary review also needs the terminal body and retention design for both families. A dimensioned section or preliminary contact drawing helps identify open items before committing to mold steel.

Can the power position and signal positions share a secondary lock?

They can be evaluated together when their seated positions and locking geometry allow it. Show both contacts at the extremes of the agreed axial fit and identify which terminal an assembler must be able to remove independently.

Can one tool make different power and signal layouts?

A common housing with different loaded positions may use exactly the same plastic part. If the plastic changes, share the cavity maps, variant quantities and features that move. We can compare a changeable insert with a dedicated tool for each configuration.

Does a quote include an electrical rating for the connector?

Please provide the operating conditions and the qualification procedure required for the finished connector. Housing inspection can document dimensions, material and molding condition. Electrical qualification uses the specified terminals, wires, counterpart and loading conditions.

Your next step

Discuss the part with its intended function.

Send the keyed cavity map, both terminal drawings and your expected quantities by variant. Mark the features you need to approve on the first plastic samples and any separate tests you want quoted on a loaded assembly.

Explore our connector injection molding service or review other connector components and mold inserts.

Request A Quote

Tell Us About Your Project

Fields marked with are required.

Before uploading sensitive files, agree any NDA and permitted sharing with your FECISION contact and the selected manufacturing partner. If you need an NDA first, select “NDA before drawings” above and send only a non-confidential overview.

By submitting this form, you agree that Fecision may use the supplied information to respond to your inquiry.