Precision connector components · Made to your design
Custom Molded Plastic Connector Backshells
FECISION quotes plastic rear hoods made to fit your connector and cable assembly. The front pocket captures the connector flange. The cable exit and clamp have to fit the harness after crimping, wrapping and routing.
Send the connector outline, the maximum finished harness width and height, and the space behind the installed connector. Include the smallest harness the clamp must hold. With these inputs we can compare exit directions, propose a split line and separate the mold cost from the price of the parts.

Product details
Three details that determine how the hood goes together
The flange pocket, angled outlet and screw bosses meet different parts of the assembly. Reviewing them separately makes it easier to identify which dimension has to change when the halves will only close under pressure.

A split hood for terminated leads
A split housing can close around a preterminated harness. Follow the flange into its pocket and check whether a conductor can cross the cover seam before the screws are started.

Room for the angled outlet
Show the exit direction on the installation drawing, viewed from a named side. Include the cable turn beyond the outlet and the neighboring port that an installer still needs to reach.

A screw boss inside the cover
A screw can bottom out while the cover still has a gap. Compare the screw reach, pilot depth and assembled cover stack before changing the torque setting.
Illustrative configurations. Final specifications follow your approved drawings.
Application fit
Which harness and housing interfaces need to fit?
Define the finished bundle at the clamp and at the narrowest point along the exit. Tape overlaps, a sleeve end or a branch can put the maximum section in a different place from the cable diameter printed on the reel.

D-sub cable hoods
A connector shell size identifies a starting footprint. The flange edges, hardware stack, terminal projection and space for a tool define the pocket behind it. Send the connector part number or revision-controlled outline and the fastening hardware to be retained.
Side-entry harness covers
A side or oblique exit can move a cable clear of a cabinet door and bring it closer to the next plug. Show the neighboring ports and the routing direction on the installed assembly. For a serviceable unit, mark which side of the cover must lift away.
Harnesses with sleeve or conduit
Mark where braid, split conduit, heat shrink or a branch starts and ends. A feature that captures a conduit groove has a different job from the clamp that grips the jacket. If both are required, identify the working location of each one.
Quote-ready inputs
What to send for a meaningful quotation
Use the same drawing revision and quantities when comparing proposals. If you need supplier approval before releasing CAD, start with your production-site qualification requirements and a non-confidential description of the work.
| Area | Please provide | Review before release |
|---|---|---|
| Connector and mounting envelope | Connector and mounting hardware drawings, flange section, locking hardware and first fixed obstruction behind the panel. | Locate the connector securely while preserving mating, wrench or driver access and cover removal. |
| Finished harness envelope | Minimum and maximum finished diameter, or width and height for a nonround bundle. Identify the wrap overlap, branch and position where each section was measured. | Check gripping at the small end and closure at the large end. Agree how much jacket marking is acceptable. |
| Cable exit and service space | Straight, side or oblique exit as viewed on the installation drawing, cable bend requirement, nearby ports and the available depth. | Check the bend through and beyond the outlet and allow room for installation and removal. |
| Material and hardware | Resin grade or service conditions, color, screw type, clamp parts and any conductive liner or braid termination hardware. | Review the molded bosses, fastening sequence and seating faces. Define who supplies each metal item. |
| Quantities and approval | Trial volume, repeat order or annual demand, housing variants and representative harnesses available for fit checks. | Quote the cavities, variant inserts, samples, report and any assembly trials as identifiable line items. |
From drawing to approval
From a cutaway drawing to a fitted first sample

Overlay the connector and harness
Put the connector flange, rear terminations, finished bundle and closest enclosure wall on the same section. Draw the order in which the harness and cover are installed. This exposes a one-piece sleeve that will no longer pass over an already assembled plug.
Review the molded halves
Place the split line and determine how the flange pockets, outlet grooves and latch hooks release from the tool. Review wall transitions at the screw bosses and identify the accessible surfaces where gate and ejector marks can be accepted.
Close samples on both harness limits
Start with the specified fastener and driver setting. Inspect the seam, verify seating at the flange, and reopen the cover to look for a pinched wire or a local jacket imprint. If the harness moves in its clamp, identify where the slip occurs before changing the rest of the hood.
Release the part and the intended fit
Agree which features are measured on the loose molded half and which checks use a complete assembly. Record the resin condition, fastener revision, harness build and inspection setup so a later repeat order can be checked in the same way.
Before you request a quote
What if our wire harness drawing gives only the individual wire diameters?
Send a finished cross-section or a sample with its sleeve, tape and branches in place. Mark the clamp station and the location of the largest section. A preliminary drawing can support a tooling discussion while those two envelope measurements are being confirmed.
Can one backshell accept more than one cable size?
The same hood may work with different saddles or reducer inserts. Compare the complete minimum and maximum harnesses, jacket stiffness and required pull resistance. We can quote alternate clamp pieces after their retention and closure requirements are defined.
Do the two housing halves need separate molds?
It depends on part size, resin, quantity and whether both halves will be ordered in equal volumes. A family mold can make both together. Separate tools or replaceable outlet inserts can make sense when exit variants or replacement covers have different demand.
Can a plastic hood be used on a shielded cable assembly?
Yes, where the assembly design provides the required conductive path. Share the braid landing, liner or contact hardware and its connection to the shell. The molded hood provides the mechanical envelope. Specify the shielding performance and test setup for the finished assembly separately.
Can a sample hood be quoted for a preterminated cable?
Yes. Send a photo of the largest feature that would have to pass through a sleeve and the order in which the connector is fitted. A split design is often worth reviewing when the connector is already installed at each end or a branch prevents threading the cover onto the harness.
Your next step
Discuss the part with its intended function.
Send the finished harness envelope, the connector flange drawing and a side view showing the available exit space. Include trial and production quantities so we can quote the hood geometry, tooling and any clamp options against the same assembly.
Explore our connector injection molding service or review other connector components and mold inserts.