If an orange branch lead stays below the lip only while the assembler holds it down, try closing the lid on a disconnected setup sample with both hands clear of the wire. The useful observation is the instant the lead rises: on transfer from the board, when the trunk rolls into the base, or just as the lip sweeps past. All three can leave the same pinch mark once the cover is closed.
Start with a disconnected development harness. Lay the lower half on the bench and orient it exactly as in the build fixture. Let the wires settle without a hand holding the branch down. Photograph the routing from above and from seam height. Even with plenty of volume in the middle, an outside wire can ride over the edge because the bundle branches too early or twists as it enters the cover.
Product design illustrations.
Locate the breakout relative to the connector
A breakout is a length of transition rather than a point. At one end the wires still share the main wrap. At the other, the smaller branch can move independently. Mark both ends relative to a repeatable connector feature, such as the rear seating face. A build board that locates the breakout from a distant cable end inherits all the intervening length variation. The hood still closes at its own fixed position.
Follow the wire farthest from the branch exit back to its terminal cavity. It may have to cross other leads before turning into the smaller leg. Then follow the nearest wire. A single cut length or an arbitrary tie placement can leave one lead taut and another with a loop at the seam. Give the terminal exits sufficient working length while keeping the crossing region inside the protected pocket. Check the cable supplier's bend limits for the selected construction.

Try rotating the wrapped trunk through the range permitted by the installation. An oval bundle or a stiff splice can roll the branch into the closing lip. If a particular clocking is required, show where it is set and how the assembler can recognize it. “Dress wires neatly” gives the person building the first harness a chance to succeed, but gives the next shift little to repeat.
Observe the moving lid as well as the closed pocket
Bring the cover toward the base slowly on a setup sample. Identify the first feature passing the branch. On a hinged cover, the lip sweeps an arc. On a drop-on cover, a guide rib or screw boss can arrive before the two flanges touch. A static section of the fully seated shell misses a wire swept sideways during the last part of this movement.
Use that observation to select a small change. Moving a permitted tape start or locator can keep the branch off the seam throughout closure. A rounded molded fence can guide loose wires into the pocket, provided its end does not introduce a sharp turn or trap a conductor against a boss. Adding a deeper general cavity will accomplish little if the first contact occurs on the rim of the lid.

Check the assembly-board handoff. The retainers in Panduit's harness board guide hold individual wires while the bundle is formed and let the assembler lift the finished bundle free. A branch held neatly on the fixture may spring outward as soon as it comes off the board. Close a sample using the production sequence. If a tie must stay on the branch, include the tie head in the hood clearance check.
Read the mark left by the seam
Open a sacrificial build sample without dragging the wires over the suspect edge. A narrow straight indentation aligned with the parting joint points to different contact than a broad mark under a saddle. Match the location on the wire to the actual boss, wall or clamp. Look for witness marks on both parts and whether the branch rotated after the sample was assembled.
Set aside damaged sample leads and follow the applicable harness inspection criteria. A conductor can still pass a simple continuity check after its insulation is pinched. Repeated bending or abrasion can then act on the same location. Define how the team will inspect the protected wiring before and after the cover closes, particularly if the assembly will later be taped, bundled or installed where it cannot be reopened.

Try the least populated variant as well as the fullest. A large bundle can hold itself below an internal bridge while a lightly populated branch floats up into the flange. Use representative terminated leads and record the wrapped harness profile at both extremes. An agreed internal routing photograph or a simple fixture check can then capture the successful arrangement more clearly than a larger cavity dimension alone.
Mark where the first interference occurs on a section of the molded backshell. If the lead rises before the lid arrives, repeat the transfer from the harness board with the branch located from the connector. If the wire remains in its pocket until the lid catches it, inspect the path of that lip. These observations point to different owners for the fix even though the damaged insulation looks alike.