A request for quotation specifies a cable diameter, but the sample has three visibly different sizes behind the connector. The wire bundle is narrow at the contacts, wider under the tape, then wider again where a sleeve overlaps the tape. Which diameter should the tooling supplier use? It depends on where the relevant opening sits and which features have to pass through it during assembly. One accurate caliper reading can still describe the wrong place.
Begin with the delivery condition. A backshell supplied loose to a harness shop sees a different assembly sequence from one supplied around a completed, wrapped cable. Ask for the wire list and the finished harness detail. The first helps explain how the bundle is built. The second defines the surfaces that can contact the molded part. A bare conductor diameter omits even its own insulation, let alone neighboring wires, shielding and wrap.
Product design illustrations.
Mark a station wherever the available space changes
Use one fixed reference, such as the rear face of the connector housing. From it, locate the inner pocket, the narrowest passage, the clamp seat and the free cable exit. At each location show the buildup present in the finished assembly. The entrance may see a round cable jacket while the clamp sits on wrapped separate wires. A sleeve further back can be irrelevant to steady-state fit yet control whether a closed collar can be slid onto the cable.
Mark the beginnings and ends of overlaps as ranges. A drawing that holds sleeve length but leaves its axial position free can put its thick edge on either side of the clamp. On taped harnesses the wrapping process also determines where layers overlap or terminate. For example, tesa's harness application guide gives instructions for the direction of taping and the final wrap for its cloth and fleece hand rolls. Use the released wrapping process for the cable you are actually quoting. tesa wire harness application guide.

Distinguish what the sample shows from what production permits. If the maximum sleeve position, wire count or tape overlap is still under review, mark it as open. A quotation can then carry an explicit assumption or allow for a replaceable exit insert. Quietly accepting the diameter of the only sample as a maximum leaves both parties with a dimension neither has approved.
Measure a soft oval without making it round
Set a short finished length in a broad support that preserves its natural shape. Record width and height across the section while noting the orientation of the major axis. If calipers are used, agree on contact conditions that avoid visibly flattening the tape. A small contact pad can sink into a soft bundle. Where the fit is critical, compare the reading with a noncontact silhouette or a shaped fixture appropriate to the required installed condition.
Consider an illustrative 12 by 8 mm oval bundle approaching an 11 mm round entrance straight on. Averaging the width and height gives 10 mm and makes the bundle look like it will fit. Trace the two outlines on the same drawing: even if you turn the bundle about its axis, its widest span is still 12 mm. If assembly depends on reshaping the bundle, establish how much compression the cable and its wrapping can tolerate before specifying that entrance.

Check several locations through the zone where the harness can move. A tie head is a local projection, a sleeve edge is an abrupt step, and a breakout changes the direction of the whole envelope. Include angular orientation if a projection can rotate toward a screw boss. A profile photographed beside a scale is useful context when the drawing also identifies the viewing direction and the axial station.
Separate the opening that passes the harness from the one that grips it
Follow the part through the build sequence. For a slide-on collar, the largest item that travels through it controls the passage. It could be a preinstalled sleeve well behind the eventual clamp seat. A split hood loaded from the side may never pass over that sleeve at all. Show which items are installed before the hood and which are added afterward. Stating that single difference can remove a costly, unnecessary enlargement from a mold proposal.
At the actual clamping location, supply the smallest approved bundle as well as the largest. Increasing an exit to clear a local maximum can leave the smaller build with poor retention. Decide which contact pressure or pull check the assembly owner requires and whether the clamp or an interchangeable insert is separately quoted. A fit envelope identifies a physical boundary. Retention and allowable insulation compression need separate acceptance criteria.

Put two sections on the backshell RFQ drawing. The first shows the widest item that must travel through the entrance during assembly, with its orientation. The second shows the smallest approved build where the clamp actually grips. Locate both from the connector, give the measurement condition and identify any limits still awaiting release. The toolmaker can now enlarge the passage for a sleeve without quietly increasing the clamp gap around the thinnest harness.