info@fecision.com

Which Drawing Should You Send for a Custom RJ45 Jack?

Empty RJ45 molded body, contact carrier and assembled shielded jack on an electronics bench

An empty molded socket, a carrier loaded with eight spring contacts and a jack ready to solder can all be described as “custom RJ45 jack” on a purchase order. Follow the tray to its next station. If that station inserts a contact block, the tray may contain only a molded RJ45 housing. If it places a jack on a PCB, somebody upstream has already loaded the contacts and any specified shield. Circle the item delivered to that station on the assembly section, then write its part number next to the price.

Product design illustrations.

Follow the empty housing through its first operation

For a bare molding, start with a dimensioned housing drawing and solid model of the same revision. Mark the surfaces that locate the contact module and the face that locates the mating plug. Include the latch shoulder and the socket mouth. If the rear of the solid model is closed off for confidentiality, give the toolmaker a section through the guide, stop and retention features. Those surfaces affect tool access and sample acceptance.

Include the mating component as reference geometry, with its allowable envelope and assembly direction. That does not turn it into a purchased line item. A housing manufacturer needs to know whether the block slides down between rails, enters from the rear or seats against a shoulder under a cover. The amount of clearance and the way a checker can reach the relevant surfaces change with that choice.

Empty molded modular jack frame viewed from the rear with the insert seating features exposed
Identify the features that guide and stop the insert while they are accessible on the bare molding.

Select a meaningful receipt check. A dimension across two accessible datums may be enough for controlling a molding feature. If acceptance also depends on seating a particular carrier, identify who provides the carrier or checking fixture, its revision and how full seating is judged. Otherwise two suppliers can quote the same drawing but allow for entirely different inspection work.

The contact module has a second drawing family

For this discussion a contact module is the spring-contact row and its carrier delivered as a unit. Confirm that definition on your own assembly drawing. The manufacturer needs the formed-contact outline, the portion captured in the plastic and the free spring position after assembly. An illustration of the socket face cannot tell the assembler which bend establishes contact height or which part of the spring must stay free to move.

Put the metal supply arrangement in writing. Contacts supplied on strip need a defined pitch, feed orientation and separation condition. Purchased loose contacts introduce a different loading operation. Plating coverage, terminal retention checks and packaging that protects exposed springs each carry a cost. These questions also reveal whether the carrier is molded around metal or populated after molding. The two routes lead to different fixtures and tools.

Fine formed spring contacts on a separate light-colored modular jack carrier
A loaded module introduces formed-contact geometry and handling requirements at the shipping boundary.

At board assembly the customer needs an installed interface

A complete jack drawing should identify its footprint, orientation, mounting features and position relative to the enclosure. Add the expected plug orientation from the front. A footprint viewed through the board can look deceptively like one viewed from the component side. A marked mating-face view and an explicit PCB view prevent an expensive mirror-image interpretation.

A manufacturer example shows how the documentation is divided. TE Connectivity lists a customer drawing, CAD models, application information and product specifications for its eight-position right-angle surface-mount modular jack. The customer drawing describes an assembly. It can orient a discussion about fit, but it does not provide the internal manufacturing definition for a new molded component.

Shielded modular jack mounted at the edge of a printed circuit board
At the PCB handoff, the footprint, retention and enclosure position become part of the interface.

Mark reference dimensions as such. The position of a cable boot outside the cabinet may be essential to reviewing access, yet the jack supplier cannot inspect that dimension on the supplied part. Give it a place on the installation drawing and keep it off the loose-housing inspection report.

If the quotation includes electrical performance, name the completed configuration, applicable specification and verification owner. State whether a shield, LEDs or magnetics belong in the assembly. An optional component changes both what must fit and what must be purchased. Assign the approved testing to the appropriate assembly level before comparing prices or promising delivery samples.

Ask a bidder to finish one sentence: “When you open the tray, you can inspect …”. An empty body lets the receiver gauge the specified slot geometry. A supplier that undertakes to deliver populated jacks has to identify which contacts, shield and revision will be in that tray. That sentence is a better comparison of two prices than the number of dimensions reproduced from the assembly drawing.

Request a Quote

Request A Quote

Tell Us About Your Project

Fields marked with are required.

Before uploading sensitive files, agree any NDA and permitted sharing with your FECISION contact and the selected manufacturing partner. If you need an NDA first, select “NDA before drawings” above and send only a non-confidential overview.

By submitting this form, you agree that Fecision may use the supplied information to respond to your inquiry.