Close the enclosure in CAD and the right-angle FAKRA shell clears the lid. Add the terminated cable and the lid rib lands halfway across the jacket. Moving the rear opening looks like a simple molding change until you notice that the rib sits beyond the end of the ferrule. The missing dimension is how much room the cable needs after it leaves the rigid assembly.
Start with a side view through the coax axis. Mark the mating face, the elbow, the last point that holds the cable straight and the first harness clip. Keep the lid rib on this drawing. Those four locations make it surprisingly easy to see which group owns the interference and which drawings would actually change if the outlet moved.
Product design illustrations.
Find the last rigid point
On some terminations, the cable leaves a crimped metal ferrule before it emerges from the plastic. On others, a boot continues to support the jacket beyond the molded opening. The cable centerline cannot begin a free bend at the housing face if there is still a rigid or closely supported section ahead. Section the termination you intend to use rather than tracing the outline of an empty shell.
The Amphenol RF cable-mount construction guide distinguishes connector orientation from cable termination options. That distinction matters on a drawing package. A note calling for a right-angle assembly tells the mold designer where the cable should head. It still takes the selected cable and termination drawings to establish what diameter, length and local relief the opening must accommodate.

Draw the jacket around the bend
A bend-radius note has two pieces of information beyond the number. Check whether it applies to a permanent installed bend or to movement during installation, and check where the cable maker measures it. Some drawings dimension to an inside surface. A CAD routing tool may sweep around a centerline. Mixing those conventions moves the outside of the jacket just where the clearance is tightest.
For a simple drawing exercise, give a round cable a 4 mm diameter and construct a bend with a 25 mm centerline radius. Its outer surface sweeps a 27 mm radius from the same center before any clearance is added. These are illustrative numbers. If a wall sits 26 mm from that center along the radial direction in the bend plane, a centerline-only layout clears it while the physical jacket touches it.
Include the short straight length before that arc. Sliding the arc toward the elbow to clear a wall may place the start of bending inside the termination. Moving the first clip instead may free the bend while putting the cable in front of a latch-release feature. Check each alternative on the same section with the cable surface, clip and release space all visible.

Walk the part into position
An installed-state section only shows the final millimeters of travel. If the connector is terminated before it enters the box, swing the elbow through the actual opening and include the ferrule and boot in that envelope. A connector that sits comfortably when mated can still need more room to align straight with the header before the key rails engage.
On a physical mock-up, place the first clip where production intends to fit it. Try the assembly order on the work instruction, then remove and refit the lid. Watch where the cable first moves. A polished witness on the rim would point toward local contact. A cable that lifts only as the lid closes would send the investigation downstream. Those observations lead to different edits.
Clocking deserves its own view from the mating face. Turning the elbow can move the exit toward a clear corner, but only if the actual assembly permits that orientation relative to the key and latch. Include the neighboring port and the path needed to disconnect it. Otherwise the apparent free corner can turn out to be the only access to the adjacent connector.

The witness mark decides where to add clearance
Mark the first contact on the enclosure section and draw a line back to the last rigid part of the termination. Where that line ends matters more than the nominal angle on the molded FAKRA housing. Show the keyed end in the same orientation on the section so a service technician can reproduce the cable route with the lid open.
Choose the correction by where the contact occurs. A rim touching the ferrule can justify reshaping the rear relief. Jacket pressure under a remote lid rib calls for a routing or enclosure decision. After the mechanical path is agreed, the assembly team can evaluate retention and electrical behavior on the specified terminated cable. A cleaner plastic opening alone answers neither question.