info@fecision.com

What Does the Plastic Housing Do in a FAKRA Coax Connector?

Molded coax connector shell, metal insert on a cable and loose crimp ferrule laid out separately

Set a loose cable hood beside a terminated coax insert. Which of them would arrive on the receiving bench if a purchase order said “FAKRA housing”? In the case of a molded FAKRA outer housing, a toolmaker can supply the keyed plastic body. The drawing may also show the metal insert, braid and ferrule so the toolmaker knows what has to fit. Those outlines matter even when the metal parts arrive from another source.

Start with an axial section of the assembly. Use one outline for the injection-molded housing and another for the purchased coax insert. Follow the shield connection from the cable into the metal body as a separate interface. The shield may be a braid on the cable, and the insert already contains an outer contact. Calling both of those features “shield” without identifying the surface is an easy way to send the wrong drawing for quotation.

Product design illustrations.

Where the plastic carries assembly loads

The shell orients the two halves, presents the code features and gives the operator a place to grip the assembly. It can also locate the insert against a molded shoulder and provide a feature that holds the insert after loading. Locate the stops on the section and mark the directions in which they resist movement. A feature that keeps the two housings latched together need not be the feature that retains the metal insert.

To review moldability, identify the contact side of the key, the front of the insert seat, the rail that guides insertion and the free span of the outer latch. A parting line on an uncritical back wall has different consequences from flash on one of these interfaces. Give the toolmaker the mating envelope and assembly direction even when procurement will supply only a bag of empty plastic bodies.

Straight-on view through the round insert tunnel of a gray plastic coax housing
Identify the seating shoulder with a section through the insert axis.

The Rosenberger FAKRA product overview illustrates how manufacturers describe complete connector families. It distinguishes housings and locking features and describes metal components separately. Use the architecture of the selected part number to identify what is present in your design. A family illustration cannot define the depth of a custom insert seat or the material of a particular latch.

Trace the signal and its return to the cable

In a coaxial connection, the inner contact, surrounding insulating material and conductive outer contact form a geometry that continues the cable interface. The outer contact must also connect to the appropriate cable shield or board-side return structure. If a termination print calls for a crimp sleeve over a prepared braid, that sleeve and the underlying metal body belong on the cable assembly definition. An exterior molded shell does not replace their electrical function.

The terminology can cause a real purchasing error. A buyer might ask for a “shielded plastic housing” while intending to buy an empty, unplated, colored shell for a conventional metal coax insert. Ask where the conductive path crosses the requested item. If a drawing actually calls for a conductive treatment or separate metal feature on the shell, obtain that specification and its inspection method. Otherwise quote the identified plastic volume and mark the metal parts as references.

Cut coaxial cable exposing the conductor, insulation and braid beside a loose metal ferrule
Follow the cable shield into its termination when defining the assembly scope.

Decide how to check the seat at the handoff

A molded part can go through dimensional inspection before the cable is available. With access from the loading side, a depth check may locate an axial stop relative to an exterior datum. A separate profile check can control the locking window. If the bore is stepped, name the exact face in the section. A flat-ended probe resting on the wrong step can give a repeatable reading and still miss the surface that seats the insert.

For an assembly fit trial, ask for the designated insert revision and the state in which it reaches the loading station. A loose insert is convenient for checking alignment. A terminated insert with a ferrule, cable and any relevant rear protection tests a different envelope. The cable may bias it to one side while it enters. State which configuration the trial uses and whether secondary retention must be engaged before evaluating the seated position.

Cable-mounted metal insert beside a populated keyed coax housing and an inspection nest
The parts meet at the insert seat. Agree on the insert revision before sampling the shell.

A good handoff also says who investigates an electrical failure. A shell with an off-center seat could obstruct mating, while a defective cable termination could break continuity even with a properly located housing. A visual check of a closed latch cannot distinguish these cases. Capture housing position, insert position and termination identification before taking the assembly apart so the interface evidence survives disassembly.

What the receiving inspector can sign off

On the incoming inspection sheet, identify the plastic part revision and the color, keyed profile and locating surfaces that can be checked on the loose shell. If seating depth is a release requirement, put the mating insert revision beside that measurement and have an insert available at the bench. Otherwise an inspector could pass a dimension on the empty molding while the cable assembly still stops short.

A photograph of the opened cable assembly now serves a purpose: label the plastic rail that steers entry, the metal outer contact that meets its counterpart and the ferrule that holds the cable termination. Each label leads back to a different drawing if that interface fails.

Request a Quote

Request A Quote

Tell Us About Your Project

Fields marked with are required.

Before uploading sensitive files, agree any NDA and permitted sharing with your FECISION contact and the selected manufacturing partner. If you need an NDA first, select “NDA before drawings” above and send only a non-confidential overview.