info@fecision.com

FAKRA Color Codes and Mechanical Keys: Which One Decides the Fit?

Three colored automotive coax connector housings with keyed openings on an inspection bench

Pick up two housings of the same color and look straight into their mating faces with the latches uppermost. One may have a rail where the other has a groove. The specified color helps a harness assembler pick the part. The profile drawing tells the toolmaker which part can physically enter its mate. To settle a fit question for a keyed FAKRA housing, you need the profiles of both halves and the direction in which they come together.

Product design illustrations.

Read both sides of the manufacturer's chart

The Amphenol RF FAKRA coding sheet pairs plug and jack views for its codes and identifies a neutral Z code. Choose the applicable row and the correct side before comparing a new housing against it. A neutral designation deserves its own check. Document which interface the particular manufacturer approves and whether that pairing is allowed in the finished equipment.

Even an approved mechanically compatible pair may be the wrong pair for a particular wiring position. In a module with two adjacent coax ports, a designer may need to prevent a lead intended for one function from reaching the other. Record the allowed and prohibited pairings at equipment level. An approved service adapter and a harness component released for normal assembly may have quite different permissions.

Raised longitudinal rib and entrance to a blue molded coax connector housing
Trace the lead-in and the full rib. A matching color tells you little about the clearance along this path.

A good drawing shows the latch and at least one unmistakable orientation feature. Label which face the viewer is looking into. Two complementary profiles placed on paper as if both were viewed from the cable end make it hard to tell whether a ridge has a passage in the counterpart. A fitted sample is useful here, but write down the two sample revisions so a later drawing change cannot slip through unnoticed.

Decide what the tool must hold

Follow a key from its entrance to full seating. The chamfer allows the housings to start, the longer flank guides the pair, and the end of the feature has to clear the counterpart as the latch reaches its stop. A section at the very front can look generous even when draft narrows the passage farther in. Ask for sections at the first overlap and at the engaged position.

Changing the pigment is straightforward on paper. Changing the key can mean changing steel on the core or cavity side, where a blend, split line or repair can affect the functional flank. If two variants share a mold through exchangeable inserts, give those inserts distinct identifiers. Verify the plastic from each configured tool against the corresponding mating profile whenever an insert changes.

Two teal coax housings in a metal parts tray beside a black inspection block
Use an approved color reference to identify a variant, and a separate mechanical check to accept the key.

Separate the color decision from the interference check

Imagine the correct profile molded in the previous variant's color after a changeover. A mechanical gauge may accept it, yet assembly operators would have the wrong visual cue. In the reverse situation a visually correct part can be stopped by a misplaced rib. Put the color acceptance method and the mechanical check on separate lines in the sample report so a pass on one cannot close the other.

For the color check, agree on the reference chip or approved molded master, viewing conditions and which surface to compare. A heavily textured face viewed next to a smooth master can look different as the light changes. For the mechanical check, identify a representative intended mate, its revision and the end condition for full seating. Keep the check close to the actual insertion direction to avoid disguising a tight flank by tilting the sample.

Two coax housing ends aligned in a mating fixture with a gap between them
Identify the mating pair on the inspection record before evaluating where the keys engage.

Check the pairing that must stop

One accepted pairing leaves an important question open. Can a nearby but prohibited mate enter far enough to cause trouble? Pick that adverse combination from the equipment's actual harness layout. Define the permitted inspection input and stopping position with the assembly owner. Forcing plastic keys against one another can damage the master and make the next result meaningless. Record which features first made contact.

If an operator reports an intermittent mismatch, ask for the housing identification, its mate, and a photograph straight into each mating face with the latch referenced. Also record whether the interference appeared on initial entry or near latch engagement. That sequence directs attention to the lead, the key flank or the final stack. A photograph of the colors alone leaves all three possibilities open.

Write down how far each pair got. “Blue fitted blue” leaves the next shift to repeat the entire test. A record that identifies both part numbers, their orientation and the point where the keys stopped lets the next shift distinguish a picking error from a change to the tool.

Request a Quote

Request A Quote

Tell Us About Your Project

Fields marked with are required.

Before uploading sensitive files, agree any NDA and permitted sharing with your FECISION contact and the selected manufacturing partner. If you need an NDA first, select “NDA before drawings” above and send only a non-confidential overview.

By submitting this form, you agree that Fecision may use the supplied information to respond to your inquiry.