The metal insert clicks into its plastic housing. A light push on the cable brings the front of the insert forward. Releasing the cable lets it settle back. Is the retaining feature failing, or is the insert moving between the two stops that were designed into the assembly? A click and an impression of looseness are useful observations, but neither one tells you where the metal is sitting.
Start by identifying what moves relative to what. Hold the housing at the mounting or locating surfaces named on its drawing and watch an accessible feature on the metal insert. Separately observe the ferrule and the cable jacket. A cable slipping inside a termination, a complete insert moving within the housing, and the entire housing rocking in its bracket can all feel like the same motion at the cable end.
Product design illustrations.
Find the two surfaces that bound the travel
Draw a section through the insertion axis. Mark the leading face of the insert that meets the forward shoulder and the rearward feature that meets the engaged retainer. Then find the corresponding faces on the plastic molding or separate locking piece. Use the deployed position of the lock. A section taken while a flexible retention feature is deflected during loading describes a different geometry.
A simple stack illustrates the distinction. If the plastic stops are 6.20 mm apart and the effective span between the two metal faces is 6.00 mm, the available travel in a rigid assembly is 0.20 mm. Those example dimensions are not an acceptance limit. If the insert has a spring preload or a tapered seat, identify which surfaces actually touch before subtracting dimensions from the drawing.

Walk the tolerances in both directions. A smaller housing stop separation paired with a longer metal span can remove clearance and obstruct full insertion. A larger separation paired with a shorter metal span gives more free movement. If a second insert supplier is under consideration, compare its actual functional faces. Matching the outside diameter of two inserts establishes little about their position between the stops.
Verify that the retention feature has returned
Check the drawing and assembly instruction for the chosen connector. The Rosenberger FAKRA family overview describes primary and secondary locking. Identify the feature and the component it locks on the specific assembly. A click from the outer housings mating is a separate event from an insert being retained inside one of those housings.
A loaded insert can depress a flexible feature on the way in, then stop against flash or a misaligned rail before the feature returns fully. The cable may feel secure under its own weight. Inspect the lock position at the specified window or from the approved reference surface. Where a separate locking piece is fitted, identify its preassembly and final positions and check the operation that moves it between them.

Measure the insert directly
Choose a reference on the molding and an accessible target on the insert that can be followed at both ends of travel. Define the contact points and the direction of approach. A probe touching a spring contact introduces motion that may belong to the contact itself. If the cable normally curves immediately behind the shell, support it so that it does not pull the insert sideways during the reading.
Take two axial positions relative to the same datum, using the procedure and small bidirectional seating loads agreed by the interface owner. Their difference describes travel under that procedure. The absolute readings also matter. An insert with a short range of movement can still sit too far rearward at both ends. That distinction disappears if only a single “play” number goes into the report.

An axial retention test asks a different question. It uses the force, direction, support and acceptance event specified for the selected assembly. Free-travel measurements on a gently seated insert do not establish a pull-out rating. Conversely, passing a retention check gives no direct answer about the location of the front interface at each end of travel. Assign separate result fields if both decisions are part of acceptance.
Make the first tool correction at the right interface
A forward reading that shifts with the molding points first to the shoulder on the FAKRA plastic housing. If the forward reading repeats but the rearward one changes, inspect the face that catches the insert after the retainer springs back. If both readings follow the same cable assembly through several shells, examine the termination before changing cavity steel. Keep the cavity and cable identifiers with each pair of readings. The original click tells you when to take those readings; their positions tell you which interface to investigate.