A straight wire drawn between the last contact and the outlet clears every feature in the lower hood. The real wire curves, has thickness, and carries a crimp barrel at one end. Fitting the upper cover can quietly push that curve against a screw post. The screws still seat because insulated wires can move under pressure. A closed seam answers only one question about the assembly.
Start the section at the last point where the termination is rigid and end it where the outgoing cable becomes free. Follow the actual construction between those points. In one hood the whole jacket makes the turn. In another, the jacket ends at the clamp and individual conductors fan out inside. These are two different bends with different governing dimensions.
Product design illustrations.
Which material is actually turning?
Mark the jacket cutback, the back of the contact barrel, the insulation support if present and the first internal obstacle. Locate each from a drawing feature that the assembly team can reproduce. A generous cavity length measured from the mating face may include the entire rigid connector insert. It tells the harness designer very little about the length available after the last crimp.
Where the jacket turns, use the cable manufacturer's limit for the specific cable and installation condition. For example, a LAPP cable data sheet specifies different bend radii for fixed installation and continuous flexing. Establish how the supplier defines the radius before translating it to a CAD centerline. Inside the stripped portion, consult the wire and termination requirements instead of applying the jacket's bend figure to each smaller conductor.

A simple conversion can expose a misleading dimension on the drawing. If a round cable is 6 mm across and the design specifies 18 mm to its inside surface, its centerline is 21 mm from the turn center and its outside surface is 24 mm away. Those three dimensions describe the very same bend. They do not establish an allowed radius for a particular cable. Agree which one is shown before either team requests a larger hood.
Draw the path of the least cooperative wire
In a populated connector there is rarely one representative centerline. A contact in the far corner may need to cross the full width of the insert, while a contact next to the outlet must turn almost immediately. Trace both from the exit of their rigid barrels. Include insulation thickness, wire crossings and the approach angle into the bundle. A fan-out drawn as a flat ribbon can acquire a second layer when it is terminated on the bench.
The first forced change of direction often matters more than the average curve. Look at the transition from an insulation support to flexible wire, the edge of the jacket cutback and the side of a screw boss. If laying on the lid forces one short lead sideways at the barrel, adding general space in the middle of the hood may accomplish little. Move or reshape the local obstacle, or revise the approved lead length and see where the bend then falls.

Give the upper half its share of the section
A rib on the underside of the lid can enter the only free space above a wire crossing. Superimpose both halves in the assembled position and inspect a section at each potential crossing. Where the lid pivots on clips before it snaps shut, also check the sweep of the rib during closure. A lead can be trapped on the way down even when it fits in the final pocket.
A clear development lid or an open section of a sacrificial sample can make wire movement easier to see. Record how the wires are dressed before closing, then reopen the sample and look for concentrated witness marks, displaced terminals or a bundle resting on an edge. Follow up with an intact production-style sample because cutting away the housing can change its stiffness and the way the cover seats.

Choose a change that resolves the interference
Shortening the strip length may carry the stiffer jacket farther around the corner. Lengthening it may move the jacket outside its intended clamp position. A different outlet angle may clear one screw boss and direct the cable straight into another. Put each proposal on the same assembled section and check the load path at the clamp before authorizing a tooling change.
After the cable clears the cabinet route, open the trial molded backshell and examine the wire that makes the tightest turn inside it. Use the intended cable, crimp, strip length and full contact population. A lead that stays clear in the lower half but moves onto a boss as the lid comes down tells you where to move the guide or free up space. Photograph the position just before contact; a picture of the closed hood hides the point of interference.

