Slide a four-port jack up to a faceplate and align the port at the left. Its plug enters cleanly. At the right end of the row the plug body rubs against a panel bridge. If increasing every cutout is the first proposal, pause and measure the centers. A small spacing error, a rotation of the entire block and a narrow individual opening can all make an end port look wrong.
Set the housing and faceplate on the same coordinate sketch. Give one direction to the row and another to port height. Decide where the assembled product locates them relative to one another. The first port may be a convenient inspection reference while the board is actually located by a pair of holes much farther away. That difference matters when translating a measurement into an enclosure change.
Product design illustrations.
Read the whole pattern before blaming one port
Measure each port center from one common reference and record its error in the row direction. A similar offset at every port suggests a location or datum-transfer issue. A steadily increasing horizontal error suggests different spacing between the two patterns. If the height changes progressively along the row, examine angular alignment between board and faceplate as well. A single outlier calls for a closer look at that port and its panel opening.
Define how the center is constructed. A molded opening with draft may have a different width at its mouth and farther in. A punch rollover can soften the upper edge of a sheet opening. Choose the section that guides the plug or admits the jack and measure opposed faces at that section. Otherwise two inspectors may calculate a center from different geometry while both believe they followed the same drawing.

Count intervals, then compare the two patterns
In a four-port example, let the jack pitch exceed the faceplate pitch by 0.06 mm. Three intervals separate the first and fourth centers, so the far end is out by 3 × 0.06 = 0.18 mm when the first centers coincide. Center the rows about their midpoints and the discrepancy splits to roughly 0.09 mm at each end. That second layout is available only if the board mounting scheme permits it: a board dowelled at the first port will still put the full 0.18 mm at the fourth. These figures illustrate accumulation; use the actual assembly references and tolerances for a fit decision.
There are two different contributors worth keeping separate. A systematic difference in pitch can grow across every interval. Independent local variation in each opening can produce an irregular pattern. Do not assume variation will cancel, and do not count the same error once as an overall span tolerance and again as a pitch contribution. Ask how the drawing controls the pattern and how the supplier intends to inspect it.

Decide what passes through the faceplate
Four individual windows require alignment at every bridge. One common window around a jack block removes the panel bridges but leaves other questions, including bezel support, shield contact where specified and what the customer sees between ports. Draw the actual jack noses, shield and front trim together. The width the panel must admit may belong to a single shell surrounding several ports.
The Molex drawing for its 43223 ganged modular jack series illustrates the value of considering the multiport assembly as a whole. Use the drawing for the exact part and option under review. A pitch copied from a similar product cannot establish where another series places its board locks or how its shield meets the panel.

Turn the measurement into a tool or fixture decision
Check the molded multiport housing before fitting the shield or soldering it to a board. Repeat the port-center measurements after those operations if the assembly permits. A row that changes shape when board locks engage deserves a different investigation from one whose as-molded span is consistently long. Where samples come from multiple mold cavities, retain the cavity identity so a local tooling offset remains visible.
A plug trial is valuable once the geometry is understood. Use the representative board, panel and cords and record which port and which neighboring positions are populated. Observe whether the metal or plastic nose strikes the panel or the wider boot catches a bridge. A good trial makes the first contact point visible without using the cable as a lever to pull the electronics into alignment.
Measure the end port of the multiport RJ45 jack housing again with the actual board mounting references fixed. If the error grew steadily from the anchored end and was there before soldering, return to the molded center span. If the bare row lined up and the offset appeared only after fastening the board, keep the mold dimensions and investigate the mounting references first. The same rub mark at port four can be the last link in either chain.