The assembly note says “cavity three is tight.” Before anyone touches the mold, ask which three. It might mean the third terminal opening on every connector. It might mean every part molded in tool cavity three. It may even be one opening on parts from that tool cavity alone. Those descriptions send the toolmaker to very different pieces of steel. Give the mold cavity and the terminal position separate columns from the first sample onward.
Keep the original rejected assembly intact if you can. It preserves the loading direction, the terminal orientation and any witness mark left at the obstruction. A second attempt can flatten a sliver of flash or bend the lance, so a successful retry does not explain why the first attempt felt wrong. Use fresh parts for comparisons.
Product design illustrations.
Arrange the samples so the pattern can survive the test
Collect inserts from consecutive shots with their mold-cavity identities intact. Lay each part with its key in the same direction. Identify an individual slot using the drawing view, including whether the numbering is shown from the mating side or the wire side. If cavity marks are absent, arrange for traceable collection at the tool before assigning a tooling cause. Parts taken at random from a mixed tote cannot establish that link.
Use fresh contacts of the same specified revision, with the same termination and orientation, across the comparison. Alternate good and suspect samples in the test sequence. Otherwise a feeder adjustment half way through the run can look like a cavity effect because one group happened to be tested last. Record whether the insert was loose on the bench or clamped in its production nest.

Find where the extra effort begins
Use a fixture and procedure appropriate to the specified insertion operation. When a force-versus-travel trace is available, keep the contact feed axis, speed, support and start reference consistent. The first engagement, movement through the cavity and final locking event offer more diagnostic detail than one peak value. Use the engineering drawing or approved assembly procedure for acceptance limits.
An increase immediately at entry suggests a burr on the contact, flash at the mouth, a displaced lead-in or a feed angle problem. Drag over a longer stretch can indicate rubbing on the cavity wall. A sharp event late in the stroke sends attention toward the retention feature or crimp envelope. Each is a place to inspect, with alternatives. The height and location of a peak alone cannot identify a particular molding condition.

Examine suspect and comparison parts under the same lighting. A line along one shutoff can be visible in every cavity but stand proud in only one. Compare location and extent with an optical section, a suitable replica or a sacrificial section where access demands it. Preserve an untouched comparison. Passing a hard pin through a delicate opening can remove the evidence or miss the corner a formed contact touches.
Take a localized finding back to the mold
When the issue follows one slot in one mold cavity across several shots, map that exact slot back to the steel using the mold-side view. Compare the corresponding core pin, its support and the opposing shutoff to the same features in an unaffected cavity. Look for local damage, offset, debris or witness marks. Document what the steel and the molded part have in common before proposing polishing or a replacement pin.

If an entire insert from one tool cavity is hard to load and there is no localized obstruction, check the part's overall position in the assembly nest and compare shrinkage and shape by cavity. A bowed body can shift several good openings off the feeder axis. If the issue follows a feeder lane when the parts are swapped, send that comparison to assembly engineering first.
A split that appears only late in a run deserves a time column as well. Keep parts from early and late shots for each cavity and test them in mixed order. Four early samples from a cool start compared with four late samples from a warm run confound elapsed time and cavity identity.
After a correction, repeat the same comparison on fresh samples, including neighboring cavities. A lower entry force alone could mean a lost retention shoulder. Verify the required seating and retention functions using the agreed test method as well. Save the annotated position map with the results so the next inspection can reproduce the same setup.
When asking for help on a rectangular connector insert, a small set of cavity-marked parts, their contact revision and one annotated force trace can be more useful than a carton of unmarked rejects. They let the reviewer connect a particular symptom to a particular opening and decide what to inspect next.