A circular carrier measures well on the bench. Once pressed into the shell, a mating pin drags near the key. Taking the carrier back out and measuring it again seems sensible, until the part springs back and the interference disappears. Keep one assembly intact. An empty carrier, a shell and the pair under load are three different measurement conditions. Each answers a different question about where the contact went.
Read the assembly section before choosing a gauge. Locate the insert band that carries the interference, any interruption at the key, the lead-in and the axial stop. Some shells retain the insert with discrete ribs or a snap feature. A smooth-cylinder press-fit assumption for one of those designs can send a team looking for an interference diameter that the drawing never intended.
Product design illustrations.
Keep the shell and carrier readings paired
Give each sample a shell identifier and a mold-cavity identifier. Record the carrier diameter at the working band, at several angular orientations and, where the drawing warrants it, at more than one axial plane. Measure the corresponding shell bore at its working surfaces. An average of several loose inserts and an average of several loose shells lose the actual combination that produced the tight or loose fit.
For a simple continuous band, the difference between free carrier outside diameter and free housing bore gives the measured free-state diametral interference for that pair at that section. It does not predict the finished contact-hole movement on its own. Wall thickness changes around the circumference, an open key slot removes support, and the housing can also deform. If roundness matters, a reading across two points is only one projection of the profile. Choose a method that sees the relevant form.

Keep the measurement environment comparable. A newly molded insert still cooling on a tray and a metal shell brought in from cold storage make an awkward pair for a close fit check. Record material condition and elapsed time when either affects the specified part. NIST explains why dimensional results depend on the reference temperature and the thermal expansion of the material in its Engineering Metrology Toolbox. Follow the agreed inspection and conditioning requirements for the material in use.
Watch the part enter the bore
Support the shell where it will resist the press load. Seat the driver against the intended load-bearing face of the carrier and leave delicate guides, contacts and keys clear. On a housing with a projecting flange, check whether the fixture bears on a stiff shoulder or on an unsupported rim. A tilted shell and a cocked driver can both create a one-sided contact mark before the working band even reaches the bore.
Preserve an assembly at the point a trial goes wrong. A shaving at the first edge suggests a different investigation from a nearly seated insert that tightens near the axial stop. Check bore entry, burrs, surface finish, key alignment and driver marks before moving steel in the injection mold. When a force-versus-travel record is available, relate changes in the trace to actual features in the section. An unexplained peak alone does not establish its cause.

If the print permits multiple finishing processes for the shell, confirm which finish was present on the samples. A small local buildup at a corner or bore entry can matter even when an interior diameter check passes. Do not modify a finished trial shell to make it fit and then use that pair as the acceptance sample without identifying the rework. The next unmodified shell could reproduce the original symptom.
Check the installed contact pattern from the interface in use
Measure seating depth at more than one angular position. Unequal readings from the same mounting plane can reveal tilt that a center reading misses. Reference the keyed contact pattern to the shell features used during mating, then compare those results with the empty insert's own reference system. A pattern that has moved as a group calls for a different correction from one cavity closing beside the key.

Check the symptom with a representative mate only after protecting any delicate contacts from damage. If rotation is lost, preserve the angular orientation of both parts. If the pair binds only after a panel nut is tightened, include that third state and the specified mounting condition. Removing a strained carrier before documenting its installed position erases the most useful part of the investigation.
Close the inspection plan with two separate acceptance statements. State which free-part dimensions belong on the molding report, and which location or mating checks belong on the assembly record. Assign the housing, fixture and representative mating samples to an owner. That arrangement prevents a bad bore from becoming a molding rejection and a distorted molded cavity from disappearing inside a passing assembly average.
For press-fitted circular contact carriers, the shell section and the press support sketch belong beside the insert drawing. Include the specified fit, shell finish, inspection state and evidence of where the bind first occurs. These details guide the toolmaker toward a change that still works after the part leaves the inspection bench.